Can I use 220 V outlets on a 15 ampere breaker and wire it up as 110 V?How can I replace a 3-way light switch with a motion sensor?How do I wire this ceiling fan?How do I properly install GFCI outlets with existing 12/3 wire in parallel and on a switch?Smoke and Sparks From Circuit Going to 6 Wire Outlet?Splitting a 220 V line into two 110 V lines?Three-way switch wiring behaving oddlyRed wire is connected to ground screw in my 110 volt receptacleReplacing outlet; found one white wire hot. How to connect?Ceiling fan with 2 switches with remoteChanging 220 to 110

In native German words, is Q always followed by U, as in English?

Why does this function call behave sensibly after calling it through a typecasted function pointer?

What does grep -v "grep" mean and do?

Should I report a leak of confidential HR information?

What does Mildred mean by this line in Three Billboards Outside Ebbing, Missouri?

In F1 classification, what is ON?

Did Wakanda officially get the stuff out of Bucky's head?

Presenting twice at same conference

Procedurally generate regions on island

How exactly is a normal force exerted, at the molecular level?

Did Chinese school textbook maps (c. 1951) "depict China as stretching even into the central Asian republics"?

How to formulate maximum function in a constraint?

What exactly is a fey/fiend/celestial spirit?

How can I convince my reader that I will not use a certain trope?

What does 自由課題 mean?

Avoid using C Strings on C++ code to trim leading whitespace

Golf the smallest circle!

Getting geometries of hurricane's 'cone of uncertainty' using shapely?

Academic recognition

Was "I have the farts, again" broadcast from the Moon to the whole world?

Do we or do we not observe (measure) superpositions all the time?

Why isn’t the tax system continuous rather than bracketed?

How to resolve this clash between multirow/multicolumn and cellcoloring?

Alphabet completion rate



Can I use 220 V outlets on a 15 ampere breaker and wire it up as 110 V?


How can I replace a 3-way light switch with a motion sensor?How do I wire this ceiling fan?How do I properly install GFCI outlets with existing 12/3 wire in parallel and on a switch?Smoke and Sparks From Circuit Going to 6 Wire Outlet?Splitting a 220 V line into two 110 V lines?Three-way switch wiring behaving oddlyRed wire is connected to ground screw in my 110 volt receptacleReplacing outlet; found one white wire hot. How to connect?Ceiling fan with 2 switches with remoteChanging 220 to 110






.everyoneloves__top-leaderboard:empty,.everyoneloves__mid-leaderboard:empty,.everyoneloves__bot-mid-leaderboard:empty margin-bottom:0;








14















I purchased a 220 V outlet and didn't realize it. My circuit is 15 amperes. I wanted to hook up a series of normal 15 ampere 110 V outlets. When I look at the outlet it looks exactly like a regular 15 ampere 110 V one?...but it has a red, blue, and yellow wire instead of black, white and green wires.



The red wire connects to the brass screw (where black normally goes), the blue wire to the silver screw (where white normally goes), and the yellow to ground (where green or brass wire normally goes). The instructions are in German and/or English.



It looks like the outlet is just a metal backing and a plastic face.



It should be ok to hook up these outlets and use them as 110 V ones, correct???



Is there anything special about the way a 220 V or 110 V are made?



Enter image description hereEnter image description here



I am in the US, near Washington, D.C.



Enter image description hereEnter image description here










share|improve this question



















  • 1





    That's really strange. Where are you on this planet, and can you post a photo of the outlet you bought?

    – ThreePhaseEel
    Jun 9 at 22:53






  • 8





    Uh, that's not a 240V outlet, can you post actual pictures of the device you have?

    – ThreePhaseEel
    Jun 9 at 23:06






  • 1





    This is the outlet I purchased. ... amazon.com/gp/aw/d/…

    – Steve
    Jun 9 at 23:06







  • 1





    It says it is a 15 amp outlet but the paperwork says 220v - 250v

    – Steve
    Jun 9 at 23:09






  • 5





    These could have been manufactured in the Philippines,where they actually put 220 on US 120V receptacles.

    – Doug
    Jun 11 at 10:16

















14















I purchased a 220 V outlet and didn't realize it. My circuit is 15 amperes. I wanted to hook up a series of normal 15 ampere 110 V outlets. When I look at the outlet it looks exactly like a regular 15 ampere 110 V one?...but it has a red, blue, and yellow wire instead of black, white and green wires.



The red wire connects to the brass screw (where black normally goes), the blue wire to the silver screw (where white normally goes), and the yellow to ground (where green or brass wire normally goes). The instructions are in German and/or English.



It looks like the outlet is just a metal backing and a plastic face.



It should be ok to hook up these outlets and use them as 110 V ones, correct???



Is there anything special about the way a 220 V or 110 V are made?



Enter image description hereEnter image description here



I am in the US, near Washington, D.C.



Enter image description hereEnter image description here










share|improve this question



















  • 1





    That's really strange. Where are you on this planet, and can you post a photo of the outlet you bought?

    – ThreePhaseEel
    Jun 9 at 22:53






  • 8





    Uh, that's not a 240V outlet, can you post actual pictures of the device you have?

    – ThreePhaseEel
    Jun 9 at 23:06






  • 1





    This is the outlet I purchased. ... amazon.com/gp/aw/d/…

    – Steve
    Jun 9 at 23:06







  • 1





    It says it is a 15 amp outlet but the paperwork says 220v - 250v

    – Steve
    Jun 9 at 23:09






  • 5





    These could have been manufactured in the Philippines,where they actually put 220 on US 120V receptacles.

    – Doug
    Jun 11 at 10:16













14












14








14


2






I purchased a 220 V outlet and didn't realize it. My circuit is 15 amperes. I wanted to hook up a series of normal 15 ampere 110 V outlets. When I look at the outlet it looks exactly like a regular 15 ampere 110 V one?...but it has a red, blue, and yellow wire instead of black, white and green wires.



The red wire connects to the brass screw (where black normally goes), the blue wire to the silver screw (where white normally goes), and the yellow to ground (where green or brass wire normally goes). The instructions are in German and/or English.



It looks like the outlet is just a metal backing and a plastic face.



It should be ok to hook up these outlets and use them as 110 V ones, correct???



Is there anything special about the way a 220 V or 110 V are made?



Enter image description hereEnter image description here



I am in the US, near Washington, D.C.



Enter image description hereEnter image description here










share|improve this question
















I purchased a 220 V outlet and didn't realize it. My circuit is 15 amperes. I wanted to hook up a series of normal 15 ampere 110 V outlets. When I look at the outlet it looks exactly like a regular 15 ampere 110 V one?...but it has a red, blue, and yellow wire instead of black, white and green wires.



The red wire connects to the brass screw (where black normally goes), the blue wire to the silver screw (where white normally goes), and the yellow to ground (where green or brass wire normally goes). The instructions are in German and/or English.



It looks like the outlet is just a metal backing and a plastic face.



It should be ok to hook up these outlets and use them as 110 V ones, correct???



Is there anything special about the way a 220 V or 110 V are made?



Enter image description hereEnter image description here



I am in the US, near Washington, D.C.



Enter image description hereEnter image description here







electrical wiring receptacle 120-240v






share|improve this question















share|improve this question













share|improve this question




share|improve this question








edited Jun 11 at 18:22









Machavity

9,2584 gold badges20 silver badges43 bronze badges




9,2584 gold badges20 silver badges43 bronze badges










asked Jun 9 at 22:12









SteveSteve

771 silver badge4 bronze badges




771 silver badge4 bronze badges







  • 1





    That's really strange. Where are you on this planet, and can you post a photo of the outlet you bought?

    – ThreePhaseEel
    Jun 9 at 22:53






  • 8





    Uh, that's not a 240V outlet, can you post actual pictures of the device you have?

    – ThreePhaseEel
    Jun 9 at 23:06






  • 1





    This is the outlet I purchased. ... amazon.com/gp/aw/d/…

    – Steve
    Jun 9 at 23:06







  • 1





    It says it is a 15 amp outlet but the paperwork says 220v - 250v

    – Steve
    Jun 9 at 23:09






  • 5





    These could have been manufactured in the Philippines,where they actually put 220 on US 120V receptacles.

    – Doug
    Jun 11 at 10:16












  • 1





    That's really strange. Where are you on this planet, and can you post a photo of the outlet you bought?

    – ThreePhaseEel
    Jun 9 at 22:53






  • 8





    Uh, that's not a 240V outlet, can you post actual pictures of the device you have?

    – ThreePhaseEel
    Jun 9 at 23:06






  • 1





    This is the outlet I purchased. ... amazon.com/gp/aw/d/…

    – Steve
    Jun 9 at 23:06







  • 1





    It says it is a 15 amp outlet but the paperwork says 220v - 250v

    – Steve
    Jun 9 at 23:09






  • 5





    These could have been manufactured in the Philippines,where they actually put 220 on US 120V receptacles.

    – Doug
    Jun 11 at 10:16







1




1





That's really strange. Where are you on this planet, and can you post a photo of the outlet you bought?

– ThreePhaseEel
Jun 9 at 22:53





That's really strange. Where are you on this planet, and can you post a photo of the outlet you bought?

– ThreePhaseEel
Jun 9 at 22:53




8




8





Uh, that's not a 240V outlet, can you post actual pictures of the device you have?

– ThreePhaseEel
Jun 9 at 23:06





Uh, that's not a 240V outlet, can you post actual pictures of the device you have?

– ThreePhaseEel
Jun 9 at 23:06




1




1





This is the outlet I purchased. ... amazon.com/gp/aw/d/…

– Steve
Jun 9 at 23:06






This is the outlet I purchased. ... amazon.com/gp/aw/d/…

– Steve
Jun 9 at 23:06





1




1





It says it is a 15 amp outlet but the paperwork says 220v - 250v

– Steve
Jun 9 at 23:09





It says it is a 15 amp outlet but the paperwork says 220v - 250v

– Steve
Jun 9 at 23:09




5




5





These could have been manufactured in the Philippines,where they actually put 220 on US 120V receptacles.

– Doug
Jun 11 at 10:16





These could have been manufactured in the Philippines,where they actually put 220 on US 120V receptacles.

– Doug
Jun 11 at 10:16










3 Answers
3






active

oldest

votes


















59














Send it back right now



You bought it off Amazon Marketplace, the world's biggest junk shop. A step down from eBay, even, because this garbage hides amongst legitimate products. Here. See what you had to notice to even spot it?



enter image description here



(Sorry for the huge size)



Note the "Sold by some_random and Fulfilled by Amazon" part. That means "Amazon Marketplace" flea market. Often, they also have goofy brand names that sound like Ikea furniture names, but you can't count on that. They're just making it up.



Standards matter. Really.



These things don't come within a mile of US safety standards. If you think that doesn’t matter, watch Big Clive on Youtube, you'll get religion right quick :)



Heck, it doesn't even comply with EU safety standards. The CE stamp and RoHS stamp are counterfeited... or to be more precise, they are a legal promise by the person inside the EU who manufactured it inside the EU or imported it into the EU, that it complies. Joe EuCitizen mail-orders it, and it ships direct from China or via Amazon's fulfillment center, Joe EuCitizen is the importer in EU law. See how that works?



In the USA the system is not promise based, but requires every piece of equipment be listed. Listed means manufacturers and importers must send off specimens of the items to Underwriter's Laboratories or equally competent testing lab, where they do destructive testing well beyond BigClive levels. Most equipment breezes through this because manufacturers know what they're doing and they're either using the same methods as were approved before, or components with the RU mark which means UL pre-approved the components.



The scam



Here is the business model of this scam. Many Chinese counterfeiters market products designed to look like legitimate product, but of course are made very, very cheaply. This scammer found this particular one on Alibaba, a bastion of this type of spew. He asked the builder "hey, can you give me USA sockets?"* The builder said "sure". (Hence the Faux German wire colors). He paid $14 each to have them individually packaged, sent a crate of these to the Amazon fulfillment warehouse (for which he pays about $3 per unit), and so they're in Prime. Probably did all this from a computer in East Asia.



So you have ten(s) of people pretending to be hundreds of companies all selling the same stuff from the same 1-3 Chinese junk mills.



Note the price is only a little bit below the price of a UL listed domestic unit from a reputable builder that is actually designed for that purpose and built properly. That's how they set prices: expensive enough to look legit and cheaper enough to make you buy. The profits are insane, and they don't even care that you return it; don't be surprised if they tell you to keep it.



Total junk. You were ripped off, request a return based on "not as described" and send it back.



How to buy not junk



If it's too late to send it back, or if they tell you to keep it, send it to Big Clive on YouTube. He will tear it down in a video and show you all the ways it would've tried to kill you.



In the future, don't buy electrical parts online; they are price prohibitive because they're usually too low value to justify shipping. Talk to your local electrical supply house, and tell them you are sick of being overcharged by Home Depot (that puts them on notice that you are price conscious).



Certainly never touch an "Amazon Marketplace" product again with a 10-foot pole.



Amazon proper is supposed to be OK, but two problems. First telling the difference in listings. Second is, if you buy something "shipped from and sold by Amazon Proper" that they legitimately sourced from Actual Leviton, and Amazon is out of stock on that, they will silently and automatically substitute the same "SKU" from an Amazon Marketplace seller — and sellers are stuffing that channel with this ugly stuff.



-



* the HA-BSD-001 code on the parts bag googles to a page on Alibaba, listing an identical device, but with a German "Schuko" socket instead of our familiar friend the NEMA 5-15. The colors, right on cue, are shown in the listing as red blue yellow/green, faux German colors.






share|improve this answer

























  • Comments are not for extended discussion; this conversation has been moved to chat.

    – Michael Karas
    Jun 12 at 5:18






  • 1





    This should be THE answer to every "I bought something on DealExtreme / AliExpress / Ebay / Amazon marketplace, and ..." question on the entire StackExchange network. Great explanation of how they peddle their junk.

    – marcelm
    Jun 12 at 10:59


















16














Send it back and get something that's listed for the job



While what you have is indeed a 120V outlet (the outlet configuration governs, not some text in a manual somewhere), this outlet is not usable in a countertop or work surface in the USA, as it is not listed or labeled for use in a countertop or work surface, as requred by NEC 406.5(E) through (G):




(E) Receptacles in Countertops. Receptacle assemblies for
installation in countertop surfaces shall be listed for countertop applications. Where receptacle assemblies for countertop
applications are required to provide ground-fault circuit-interrupter protection for personnel in accordance with 210.8,
such assemblies shall be permitted to be listed as GFCI receptacle assemblies for countertop applications.



(F) Receptacles in Work Surfaces. Receptacle assemblies and
GFCI receptacle assemblies listed for work surface or countertop applications shall be permitted to be installed in work
surfaces.



(G) Receptacle Orientation. Receptacles shall not be installed
in a face-up position in or on countertop surfaces or work
surfaces unless listed for countertop or work surface applications.




So, you'll need to return it and get something else that has an actual UL/ETL/... listing for this application.






share|improve this answer


















  • 1





    Ok thanks. Unfortunately I bought 7 of these last year...so probably just threw money away at this point. I do have a GFI wired in first in the series of connections. I thought that would suffice with these non Gfci outlets. Still, probably safer if I get 7 outlets with GFI in them. Thanks for your advice and help

    – Steve
    Jun 10 at 0:52






  • 2





    @Steve -- the issue isn't the GFCI, it's the lack of listing for countertop service. It means that you'll probably open them up a year down the road to find a mess inside when you're trying to troubleshoot mystery GFCI trips

    – ThreePhaseEel
    Jun 10 at 2:42






  • 1





    @Steve one GFCI protecting the downline is the far saner way to do that. Anyway GFCI will not protect you from these items' mayhem. AFCI would have a better shot at doing so, but there are still serious risks.

    – Harper
    Jun 10 at 20:09


















11














This is a 220V outlet (note horizontal "live" slot on the right):



(Photo of a NEMA 6-20 outlet)



And this is a 110V outlet (vertical "live" slot):



(Photo of a NEMA 5-20 outlet)



Pictures valid in USA.



Look at these two outlets. I recently grabbed a 110 thinking it was a 220.



There is a difference a 220 plug won’t fit a 110 and a 110 won’t fit a 220. If your 110 plugs fit the outlets you have the will work as long as you wire a hot a neutral and a ground to the correct screws.






share|improve this answer




















  • 1





    amazon.com/gp/aw/d/…. It says it is a 15amp device....but the paperwork says it is 220v

    – Steve
    Jun 9 at 23:06







  • 1





    Thanks @grawity

    – Kris
    Jun 10 at 14:59











  • While the other answers make good points about buying safe products, this is the actual answer on why it will not work even if it was a perfectly safe socket.

    – SQB
    Jun 11 at 8:50













Your Answer








StackExchange.ready(function()
var channelOptions =
tags: "".split(" "),
id: "73"
;
initTagRenderer("".split(" "), "".split(" "), channelOptions);

StackExchange.using("externalEditor", function()
// Have to fire editor after snippets, if snippets enabled
if (StackExchange.settings.snippets.snippetsEnabled)
StackExchange.using("snippets", function()
createEditor();
);

else
createEditor();

);

function createEditor()
StackExchange.prepareEditor(
heartbeatType: 'answer',
autoActivateHeartbeat: false,
convertImagesToLinks: false,
noModals: true,
showLowRepImageUploadWarning: true,
reputationToPostImages: null,
bindNavPrevention: true,
postfix: "",
imageUploader:
brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
allowUrls: true
,
noCode: true, onDemand: true,
discardSelector: ".discard-answer"
,immediatelyShowMarkdownHelp:true
);



);













draft saved

draft discarded


















StackExchange.ready(
function ()
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f166899%2fcan-i-use-220-v-outlets-on-a-15-ampere-breaker-and-wire-it-up-as-110-v%23new-answer', 'question_page');

);

Post as a guest















Required, but never shown

























3 Answers
3






active

oldest

votes








3 Answers
3






active

oldest

votes









active

oldest

votes






active

oldest

votes









59














Send it back right now



You bought it off Amazon Marketplace, the world's biggest junk shop. A step down from eBay, even, because this garbage hides amongst legitimate products. Here. See what you had to notice to even spot it?



enter image description here



(Sorry for the huge size)



Note the "Sold by some_random and Fulfilled by Amazon" part. That means "Amazon Marketplace" flea market. Often, they also have goofy brand names that sound like Ikea furniture names, but you can't count on that. They're just making it up.



Standards matter. Really.



These things don't come within a mile of US safety standards. If you think that doesn’t matter, watch Big Clive on Youtube, you'll get religion right quick :)



Heck, it doesn't even comply with EU safety standards. The CE stamp and RoHS stamp are counterfeited... or to be more precise, they are a legal promise by the person inside the EU who manufactured it inside the EU or imported it into the EU, that it complies. Joe EuCitizen mail-orders it, and it ships direct from China or via Amazon's fulfillment center, Joe EuCitizen is the importer in EU law. See how that works?



In the USA the system is not promise based, but requires every piece of equipment be listed. Listed means manufacturers and importers must send off specimens of the items to Underwriter's Laboratories or equally competent testing lab, where they do destructive testing well beyond BigClive levels. Most equipment breezes through this because manufacturers know what they're doing and they're either using the same methods as were approved before, or components with the RU mark which means UL pre-approved the components.



The scam



Here is the business model of this scam. Many Chinese counterfeiters market products designed to look like legitimate product, but of course are made very, very cheaply. This scammer found this particular one on Alibaba, a bastion of this type of spew. He asked the builder "hey, can you give me USA sockets?"* The builder said "sure". (Hence the Faux German wire colors). He paid $14 each to have them individually packaged, sent a crate of these to the Amazon fulfillment warehouse (for which he pays about $3 per unit), and so they're in Prime. Probably did all this from a computer in East Asia.



So you have ten(s) of people pretending to be hundreds of companies all selling the same stuff from the same 1-3 Chinese junk mills.



Note the price is only a little bit below the price of a UL listed domestic unit from a reputable builder that is actually designed for that purpose and built properly. That's how they set prices: expensive enough to look legit and cheaper enough to make you buy. The profits are insane, and they don't even care that you return it; don't be surprised if they tell you to keep it.



Total junk. You were ripped off, request a return based on "not as described" and send it back.



How to buy not junk



If it's too late to send it back, or if they tell you to keep it, send it to Big Clive on YouTube. He will tear it down in a video and show you all the ways it would've tried to kill you.



In the future, don't buy electrical parts online; they are price prohibitive because they're usually too low value to justify shipping. Talk to your local electrical supply house, and tell them you are sick of being overcharged by Home Depot (that puts them on notice that you are price conscious).



Certainly never touch an "Amazon Marketplace" product again with a 10-foot pole.



Amazon proper is supposed to be OK, but two problems. First telling the difference in listings. Second is, if you buy something "shipped from and sold by Amazon Proper" that they legitimately sourced from Actual Leviton, and Amazon is out of stock on that, they will silently and automatically substitute the same "SKU" from an Amazon Marketplace seller — and sellers are stuffing that channel with this ugly stuff.



-



* the HA-BSD-001 code on the parts bag googles to a page on Alibaba, listing an identical device, but with a German "Schuko" socket instead of our familiar friend the NEMA 5-15. The colors, right on cue, are shown in the listing as red blue yellow/green, faux German colors.






share|improve this answer

























  • Comments are not for extended discussion; this conversation has been moved to chat.

    – Michael Karas
    Jun 12 at 5:18






  • 1





    This should be THE answer to every "I bought something on DealExtreme / AliExpress / Ebay / Amazon marketplace, and ..." question on the entire StackExchange network. Great explanation of how they peddle their junk.

    – marcelm
    Jun 12 at 10:59















59














Send it back right now



You bought it off Amazon Marketplace, the world's biggest junk shop. A step down from eBay, even, because this garbage hides amongst legitimate products. Here. See what you had to notice to even spot it?



enter image description here



(Sorry for the huge size)



Note the "Sold by some_random and Fulfilled by Amazon" part. That means "Amazon Marketplace" flea market. Often, they also have goofy brand names that sound like Ikea furniture names, but you can't count on that. They're just making it up.



Standards matter. Really.



These things don't come within a mile of US safety standards. If you think that doesn’t matter, watch Big Clive on Youtube, you'll get religion right quick :)



Heck, it doesn't even comply with EU safety standards. The CE stamp and RoHS stamp are counterfeited... or to be more precise, they are a legal promise by the person inside the EU who manufactured it inside the EU or imported it into the EU, that it complies. Joe EuCitizen mail-orders it, and it ships direct from China or via Amazon's fulfillment center, Joe EuCitizen is the importer in EU law. See how that works?



In the USA the system is not promise based, but requires every piece of equipment be listed. Listed means manufacturers and importers must send off specimens of the items to Underwriter's Laboratories or equally competent testing lab, where they do destructive testing well beyond BigClive levels. Most equipment breezes through this because manufacturers know what they're doing and they're either using the same methods as were approved before, or components with the RU mark which means UL pre-approved the components.



The scam



Here is the business model of this scam. Many Chinese counterfeiters market products designed to look like legitimate product, but of course are made very, very cheaply. This scammer found this particular one on Alibaba, a bastion of this type of spew. He asked the builder "hey, can you give me USA sockets?"* The builder said "sure". (Hence the Faux German wire colors). He paid $14 each to have them individually packaged, sent a crate of these to the Amazon fulfillment warehouse (for which he pays about $3 per unit), and so they're in Prime. Probably did all this from a computer in East Asia.



So you have ten(s) of people pretending to be hundreds of companies all selling the same stuff from the same 1-3 Chinese junk mills.



Note the price is only a little bit below the price of a UL listed domestic unit from a reputable builder that is actually designed for that purpose and built properly. That's how they set prices: expensive enough to look legit and cheaper enough to make you buy. The profits are insane, and they don't even care that you return it; don't be surprised if they tell you to keep it.



Total junk. You were ripped off, request a return based on "not as described" and send it back.



How to buy not junk



If it's too late to send it back, or if they tell you to keep it, send it to Big Clive on YouTube. He will tear it down in a video and show you all the ways it would've tried to kill you.



In the future, don't buy electrical parts online; they are price prohibitive because they're usually too low value to justify shipping. Talk to your local electrical supply house, and tell them you are sick of being overcharged by Home Depot (that puts them on notice that you are price conscious).



Certainly never touch an "Amazon Marketplace" product again with a 10-foot pole.



Amazon proper is supposed to be OK, but two problems. First telling the difference in listings. Second is, if you buy something "shipped from and sold by Amazon Proper" that they legitimately sourced from Actual Leviton, and Amazon is out of stock on that, they will silently and automatically substitute the same "SKU" from an Amazon Marketplace seller — and sellers are stuffing that channel with this ugly stuff.



-



* the HA-BSD-001 code on the parts bag googles to a page on Alibaba, listing an identical device, but with a German "Schuko" socket instead of our familiar friend the NEMA 5-15. The colors, right on cue, are shown in the listing as red blue yellow/green, faux German colors.






share|improve this answer

























  • Comments are not for extended discussion; this conversation has been moved to chat.

    – Michael Karas
    Jun 12 at 5:18






  • 1





    This should be THE answer to every "I bought something on DealExtreme / AliExpress / Ebay / Amazon marketplace, and ..." question on the entire StackExchange network. Great explanation of how they peddle their junk.

    – marcelm
    Jun 12 at 10:59













59












59








59







Send it back right now



You bought it off Amazon Marketplace, the world's biggest junk shop. A step down from eBay, even, because this garbage hides amongst legitimate products. Here. See what you had to notice to even spot it?



enter image description here



(Sorry for the huge size)



Note the "Sold by some_random and Fulfilled by Amazon" part. That means "Amazon Marketplace" flea market. Often, they also have goofy brand names that sound like Ikea furniture names, but you can't count on that. They're just making it up.



Standards matter. Really.



These things don't come within a mile of US safety standards. If you think that doesn’t matter, watch Big Clive on Youtube, you'll get religion right quick :)



Heck, it doesn't even comply with EU safety standards. The CE stamp and RoHS stamp are counterfeited... or to be more precise, they are a legal promise by the person inside the EU who manufactured it inside the EU or imported it into the EU, that it complies. Joe EuCitizen mail-orders it, and it ships direct from China or via Amazon's fulfillment center, Joe EuCitizen is the importer in EU law. See how that works?



In the USA the system is not promise based, but requires every piece of equipment be listed. Listed means manufacturers and importers must send off specimens of the items to Underwriter's Laboratories or equally competent testing lab, where they do destructive testing well beyond BigClive levels. Most equipment breezes through this because manufacturers know what they're doing and they're either using the same methods as were approved before, or components with the RU mark which means UL pre-approved the components.



The scam



Here is the business model of this scam. Many Chinese counterfeiters market products designed to look like legitimate product, but of course are made very, very cheaply. This scammer found this particular one on Alibaba, a bastion of this type of spew. He asked the builder "hey, can you give me USA sockets?"* The builder said "sure". (Hence the Faux German wire colors). He paid $14 each to have them individually packaged, sent a crate of these to the Amazon fulfillment warehouse (for which he pays about $3 per unit), and so they're in Prime. Probably did all this from a computer in East Asia.



So you have ten(s) of people pretending to be hundreds of companies all selling the same stuff from the same 1-3 Chinese junk mills.



Note the price is only a little bit below the price of a UL listed domestic unit from a reputable builder that is actually designed for that purpose and built properly. That's how they set prices: expensive enough to look legit and cheaper enough to make you buy. The profits are insane, and they don't even care that you return it; don't be surprised if they tell you to keep it.



Total junk. You were ripped off, request a return based on "not as described" and send it back.



How to buy not junk



If it's too late to send it back, or if they tell you to keep it, send it to Big Clive on YouTube. He will tear it down in a video and show you all the ways it would've tried to kill you.



In the future, don't buy electrical parts online; they are price prohibitive because they're usually too low value to justify shipping. Talk to your local electrical supply house, and tell them you are sick of being overcharged by Home Depot (that puts them on notice that you are price conscious).



Certainly never touch an "Amazon Marketplace" product again with a 10-foot pole.



Amazon proper is supposed to be OK, but two problems. First telling the difference in listings. Second is, if you buy something "shipped from and sold by Amazon Proper" that they legitimately sourced from Actual Leviton, and Amazon is out of stock on that, they will silently and automatically substitute the same "SKU" from an Amazon Marketplace seller — and sellers are stuffing that channel with this ugly stuff.



-



* the HA-BSD-001 code on the parts bag googles to a page on Alibaba, listing an identical device, but with a German "Schuko" socket instead of our familiar friend the NEMA 5-15. The colors, right on cue, are shown in the listing as red blue yellow/green, faux German colors.






share|improve this answer















Send it back right now



You bought it off Amazon Marketplace, the world's biggest junk shop. A step down from eBay, even, because this garbage hides amongst legitimate products. Here. See what you had to notice to even spot it?



enter image description here



(Sorry for the huge size)



Note the "Sold by some_random and Fulfilled by Amazon" part. That means "Amazon Marketplace" flea market. Often, they also have goofy brand names that sound like Ikea furniture names, but you can't count on that. They're just making it up.



Standards matter. Really.



These things don't come within a mile of US safety standards. If you think that doesn’t matter, watch Big Clive on Youtube, you'll get religion right quick :)



Heck, it doesn't even comply with EU safety standards. The CE stamp and RoHS stamp are counterfeited... or to be more precise, they are a legal promise by the person inside the EU who manufactured it inside the EU or imported it into the EU, that it complies. Joe EuCitizen mail-orders it, and it ships direct from China or via Amazon's fulfillment center, Joe EuCitizen is the importer in EU law. See how that works?



In the USA the system is not promise based, but requires every piece of equipment be listed. Listed means manufacturers and importers must send off specimens of the items to Underwriter's Laboratories or equally competent testing lab, where they do destructive testing well beyond BigClive levels. Most equipment breezes through this because manufacturers know what they're doing and they're either using the same methods as were approved before, or components with the RU mark which means UL pre-approved the components.



The scam



Here is the business model of this scam. Many Chinese counterfeiters market products designed to look like legitimate product, but of course are made very, very cheaply. This scammer found this particular one on Alibaba, a bastion of this type of spew. He asked the builder "hey, can you give me USA sockets?"* The builder said "sure". (Hence the Faux German wire colors). He paid $14 each to have them individually packaged, sent a crate of these to the Amazon fulfillment warehouse (for which he pays about $3 per unit), and so they're in Prime. Probably did all this from a computer in East Asia.



So you have ten(s) of people pretending to be hundreds of companies all selling the same stuff from the same 1-3 Chinese junk mills.



Note the price is only a little bit below the price of a UL listed domestic unit from a reputable builder that is actually designed for that purpose and built properly. That's how they set prices: expensive enough to look legit and cheaper enough to make you buy. The profits are insane, and they don't even care that you return it; don't be surprised if they tell you to keep it.



Total junk. You were ripped off, request a return based on "not as described" and send it back.



How to buy not junk



If it's too late to send it back, or if they tell you to keep it, send it to Big Clive on YouTube. He will tear it down in a video and show you all the ways it would've tried to kill you.



In the future, don't buy electrical parts online; they are price prohibitive because they're usually too low value to justify shipping. Talk to your local electrical supply house, and tell them you are sick of being overcharged by Home Depot (that puts them on notice that you are price conscious).



Certainly never touch an "Amazon Marketplace" product again with a 10-foot pole.



Amazon proper is supposed to be OK, but two problems. First telling the difference in listings. Second is, if you buy something "shipped from and sold by Amazon Proper" that they legitimately sourced from Actual Leviton, and Amazon is out of stock on that, they will silently and automatically substitute the same "SKU" from an Amazon Marketplace seller — and sellers are stuffing that channel with this ugly stuff.



-



* the HA-BSD-001 code on the parts bag googles to a page on Alibaba, listing an identical device, but with a German "Schuko" socket instead of our familiar friend the NEMA 5-15. The colors, right on cue, are shown in the listing as red blue yellow/green, faux German colors.







share|improve this answer














share|improve this answer



share|improve this answer








edited Jun 10 at 18:24

























answered Jun 10 at 1:03









HarperHarper

84.1k5 gold badges61 silver badges172 bronze badges




84.1k5 gold badges61 silver badges172 bronze badges












  • Comments are not for extended discussion; this conversation has been moved to chat.

    – Michael Karas
    Jun 12 at 5:18






  • 1





    This should be THE answer to every "I bought something on DealExtreme / AliExpress / Ebay / Amazon marketplace, and ..." question on the entire StackExchange network. Great explanation of how they peddle their junk.

    – marcelm
    Jun 12 at 10:59

















  • Comments are not for extended discussion; this conversation has been moved to chat.

    – Michael Karas
    Jun 12 at 5:18






  • 1





    This should be THE answer to every "I bought something on DealExtreme / AliExpress / Ebay / Amazon marketplace, and ..." question on the entire StackExchange network. Great explanation of how they peddle their junk.

    – marcelm
    Jun 12 at 10:59
















Comments are not for extended discussion; this conversation has been moved to chat.

– Michael Karas
Jun 12 at 5:18





Comments are not for extended discussion; this conversation has been moved to chat.

– Michael Karas
Jun 12 at 5:18




1




1





This should be THE answer to every "I bought something on DealExtreme / AliExpress / Ebay / Amazon marketplace, and ..." question on the entire StackExchange network. Great explanation of how they peddle their junk.

– marcelm
Jun 12 at 10:59





This should be THE answer to every "I bought something on DealExtreme / AliExpress / Ebay / Amazon marketplace, and ..." question on the entire StackExchange network. Great explanation of how they peddle their junk.

– marcelm
Jun 12 at 10:59













16














Send it back and get something that's listed for the job



While what you have is indeed a 120V outlet (the outlet configuration governs, not some text in a manual somewhere), this outlet is not usable in a countertop or work surface in the USA, as it is not listed or labeled for use in a countertop or work surface, as requred by NEC 406.5(E) through (G):




(E) Receptacles in Countertops. Receptacle assemblies for
installation in countertop surfaces shall be listed for countertop applications. Where receptacle assemblies for countertop
applications are required to provide ground-fault circuit-interrupter protection for personnel in accordance with 210.8,
such assemblies shall be permitted to be listed as GFCI receptacle assemblies for countertop applications.



(F) Receptacles in Work Surfaces. Receptacle assemblies and
GFCI receptacle assemblies listed for work surface or countertop applications shall be permitted to be installed in work
surfaces.



(G) Receptacle Orientation. Receptacles shall not be installed
in a face-up position in or on countertop surfaces or work
surfaces unless listed for countertop or work surface applications.




So, you'll need to return it and get something else that has an actual UL/ETL/... listing for this application.






share|improve this answer


















  • 1





    Ok thanks. Unfortunately I bought 7 of these last year...so probably just threw money away at this point. I do have a GFI wired in first in the series of connections. I thought that would suffice with these non Gfci outlets. Still, probably safer if I get 7 outlets with GFI in them. Thanks for your advice and help

    – Steve
    Jun 10 at 0:52






  • 2





    @Steve -- the issue isn't the GFCI, it's the lack of listing for countertop service. It means that you'll probably open them up a year down the road to find a mess inside when you're trying to troubleshoot mystery GFCI trips

    – ThreePhaseEel
    Jun 10 at 2:42






  • 1





    @Steve one GFCI protecting the downline is the far saner way to do that. Anyway GFCI will not protect you from these items' mayhem. AFCI would have a better shot at doing so, but there are still serious risks.

    – Harper
    Jun 10 at 20:09















16














Send it back and get something that's listed for the job



While what you have is indeed a 120V outlet (the outlet configuration governs, not some text in a manual somewhere), this outlet is not usable in a countertop or work surface in the USA, as it is not listed or labeled for use in a countertop or work surface, as requred by NEC 406.5(E) through (G):




(E) Receptacles in Countertops. Receptacle assemblies for
installation in countertop surfaces shall be listed for countertop applications. Where receptacle assemblies for countertop
applications are required to provide ground-fault circuit-interrupter protection for personnel in accordance with 210.8,
such assemblies shall be permitted to be listed as GFCI receptacle assemblies for countertop applications.



(F) Receptacles in Work Surfaces. Receptacle assemblies and
GFCI receptacle assemblies listed for work surface or countertop applications shall be permitted to be installed in work
surfaces.



(G) Receptacle Orientation. Receptacles shall not be installed
in a face-up position in or on countertop surfaces or work
surfaces unless listed for countertop or work surface applications.




So, you'll need to return it and get something else that has an actual UL/ETL/... listing for this application.






share|improve this answer


















  • 1





    Ok thanks. Unfortunately I bought 7 of these last year...so probably just threw money away at this point. I do have a GFI wired in first in the series of connections. I thought that would suffice with these non Gfci outlets. Still, probably safer if I get 7 outlets with GFI in them. Thanks for your advice and help

    – Steve
    Jun 10 at 0:52






  • 2





    @Steve -- the issue isn't the GFCI, it's the lack of listing for countertop service. It means that you'll probably open them up a year down the road to find a mess inside when you're trying to troubleshoot mystery GFCI trips

    – ThreePhaseEel
    Jun 10 at 2:42






  • 1





    @Steve one GFCI protecting the downline is the far saner way to do that. Anyway GFCI will not protect you from these items' mayhem. AFCI would have a better shot at doing so, but there are still serious risks.

    – Harper
    Jun 10 at 20:09













16












16








16







Send it back and get something that's listed for the job



While what you have is indeed a 120V outlet (the outlet configuration governs, not some text in a manual somewhere), this outlet is not usable in a countertop or work surface in the USA, as it is not listed or labeled for use in a countertop or work surface, as requred by NEC 406.5(E) through (G):




(E) Receptacles in Countertops. Receptacle assemblies for
installation in countertop surfaces shall be listed for countertop applications. Where receptacle assemblies for countertop
applications are required to provide ground-fault circuit-interrupter protection for personnel in accordance with 210.8,
such assemblies shall be permitted to be listed as GFCI receptacle assemblies for countertop applications.



(F) Receptacles in Work Surfaces. Receptacle assemblies and
GFCI receptacle assemblies listed for work surface or countertop applications shall be permitted to be installed in work
surfaces.



(G) Receptacle Orientation. Receptacles shall not be installed
in a face-up position in or on countertop surfaces or work
surfaces unless listed for countertop or work surface applications.




So, you'll need to return it and get something else that has an actual UL/ETL/... listing for this application.






share|improve this answer













Send it back and get something that's listed for the job



While what you have is indeed a 120V outlet (the outlet configuration governs, not some text in a manual somewhere), this outlet is not usable in a countertop or work surface in the USA, as it is not listed or labeled for use in a countertop or work surface, as requred by NEC 406.5(E) through (G):




(E) Receptacles in Countertops. Receptacle assemblies for
installation in countertop surfaces shall be listed for countertop applications. Where receptacle assemblies for countertop
applications are required to provide ground-fault circuit-interrupter protection for personnel in accordance with 210.8,
such assemblies shall be permitted to be listed as GFCI receptacle assemblies for countertop applications.



(F) Receptacles in Work Surfaces. Receptacle assemblies and
GFCI receptacle assemblies listed for work surface or countertop applications shall be permitted to be installed in work
surfaces.



(G) Receptacle Orientation. Receptacles shall not be installed
in a face-up position in or on countertop surfaces or work
surfaces unless listed for countertop or work surface applications.




So, you'll need to return it and get something else that has an actual UL/ETL/... listing for this application.







share|improve this answer












share|improve this answer



share|improve this answer










answered Jun 10 at 0:14









ThreePhaseEelThreePhaseEel

35.2k11 gold badges55 silver badges108 bronze badges




35.2k11 gold badges55 silver badges108 bronze badges







  • 1





    Ok thanks. Unfortunately I bought 7 of these last year...so probably just threw money away at this point. I do have a GFI wired in first in the series of connections. I thought that would suffice with these non Gfci outlets. Still, probably safer if I get 7 outlets with GFI in them. Thanks for your advice and help

    – Steve
    Jun 10 at 0:52






  • 2





    @Steve -- the issue isn't the GFCI, it's the lack of listing for countertop service. It means that you'll probably open them up a year down the road to find a mess inside when you're trying to troubleshoot mystery GFCI trips

    – ThreePhaseEel
    Jun 10 at 2:42






  • 1





    @Steve one GFCI protecting the downline is the far saner way to do that. Anyway GFCI will not protect you from these items' mayhem. AFCI would have a better shot at doing so, but there are still serious risks.

    – Harper
    Jun 10 at 20:09












  • 1





    Ok thanks. Unfortunately I bought 7 of these last year...so probably just threw money away at this point. I do have a GFI wired in first in the series of connections. I thought that would suffice with these non Gfci outlets. Still, probably safer if I get 7 outlets with GFI in them. Thanks for your advice and help

    – Steve
    Jun 10 at 0:52






  • 2





    @Steve -- the issue isn't the GFCI, it's the lack of listing for countertop service. It means that you'll probably open them up a year down the road to find a mess inside when you're trying to troubleshoot mystery GFCI trips

    – ThreePhaseEel
    Jun 10 at 2:42






  • 1





    @Steve one GFCI protecting the downline is the far saner way to do that. Anyway GFCI will not protect you from these items' mayhem. AFCI would have a better shot at doing so, but there are still serious risks.

    – Harper
    Jun 10 at 20:09







1




1





Ok thanks. Unfortunately I bought 7 of these last year...so probably just threw money away at this point. I do have a GFI wired in first in the series of connections. I thought that would suffice with these non Gfci outlets. Still, probably safer if I get 7 outlets with GFI in them. Thanks for your advice and help

– Steve
Jun 10 at 0:52





Ok thanks. Unfortunately I bought 7 of these last year...so probably just threw money away at this point. I do have a GFI wired in first in the series of connections. I thought that would suffice with these non Gfci outlets. Still, probably safer if I get 7 outlets with GFI in them. Thanks for your advice and help

– Steve
Jun 10 at 0:52




2




2





@Steve -- the issue isn't the GFCI, it's the lack of listing for countertop service. It means that you'll probably open them up a year down the road to find a mess inside when you're trying to troubleshoot mystery GFCI trips

– ThreePhaseEel
Jun 10 at 2:42





@Steve -- the issue isn't the GFCI, it's the lack of listing for countertop service. It means that you'll probably open them up a year down the road to find a mess inside when you're trying to troubleshoot mystery GFCI trips

– ThreePhaseEel
Jun 10 at 2:42




1




1





@Steve one GFCI protecting the downline is the far saner way to do that. Anyway GFCI will not protect you from these items' mayhem. AFCI would have a better shot at doing so, but there are still serious risks.

– Harper
Jun 10 at 20:09





@Steve one GFCI protecting the downline is the far saner way to do that. Anyway GFCI will not protect you from these items' mayhem. AFCI would have a better shot at doing so, but there are still serious risks.

– Harper
Jun 10 at 20:09











11














This is a 220V outlet (note horizontal "live" slot on the right):



(Photo of a NEMA 6-20 outlet)



And this is a 110V outlet (vertical "live" slot):



(Photo of a NEMA 5-20 outlet)



Pictures valid in USA.



Look at these two outlets. I recently grabbed a 110 thinking it was a 220.



There is a difference a 220 plug won’t fit a 110 and a 110 won’t fit a 220. If your 110 plugs fit the outlets you have the will work as long as you wire a hot a neutral and a ground to the correct screws.






share|improve this answer




















  • 1





    amazon.com/gp/aw/d/…. It says it is a 15amp device....but the paperwork says it is 220v

    – Steve
    Jun 9 at 23:06







  • 1





    Thanks @grawity

    – Kris
    Jun 10 at 14:59











  • While the other answers make good points about buying safe products, this is the actual answer on why it will not work even if it was a perfectly safe socket.

    – SQB
    Jun 11 at 8:50















11














This is a 220V outlet (note horizontal "live" slot on the right):



(Photo of a NEMA 6-20 outlet)



And this is a 110V outlet (vertical "live" slot):



(Photo of a NEMA 5-20 outlet)



Pictures valid in USA.



Look at these two outlets. I recently grabbed a 110 thinking it was a 220.



There is a difference a 220 plug won’t fit a 110 and a 110 won’t fit a 220. If your 110 plugs fit the outlets you have the will work as long as you wire a hot a neutral and a ground to the correct screws.






share|improve this answer




















  • 1





    amazon.com/gp/aw/d/…. It says it is a 15amp device....but the paperwork says it is 220v

    – Steve
    Jun 9 at 23:06







  • 1





    Thanks @grawity

    – Kris
    Jun 10 at 14:59











  • While the other answers make good points about buying safe products, this is the actual answer on why it will not work even if it was a perfectly safe socket.

    – SQB
    Jun 11 at 8:50













11












11








11







This is a 220V outlet (note horizontal "live" slot on the right):



(Photo of a NEMA 6-20 outlet)



And this is a 110V outlet (vertical "live" slot):



(Photo of a NEMA 5-20 outlet)



Pictures valid in USA.



Look at these two outlets. I recently grabbed a 110 thinking it was a 220.



There is a difference a 220 plug won’t fit a 110 and a 110 won’t fit a 220. If your 110 plugs fit the outlets you have the will work as long as you wire a hot a neutral and a ground to the correct screws.






share|improve this answer















This is a 220V outlet (note horizontal "live" slot on the right):



(Photo of a NEMA 6-20 outlet)



And this is a 110V outlet (vertical "live" slot):



(Photo of a NEMA 5-20 outlet)



Pictures valid in USA.



Look at these two outlets. I recently grabbed a 110 thinking it was a 220.



There is a difference a 220 plug won’t fit a 110 and a 110 won’t fit a 220. If your 110 plugs fit the outlets you have the will work as long as you wire a hot a neutral and a ground to the correct screws.







share|improve this answer














share|improve this answer



share|improve this answer








edited Jun 10 at 12:17









grawity

1034 bronze badges




1034 bronze badges










answered Jun 9 at 22:39









KrisKris

1,7741 gold badge6 silver badges15 bronze badges




1,7741 gold badge6 silver badges15 bronze badges







  • 1





    amazon.com/gp/aw/d/…. It says it is a 15amp device....but the paperwork says it is 220v

    – Steve
    Jun 9 at 23:06







  • 1





    Thanks @grawity

    – Kris
    Jun 10 at 14:59











  • While the other answers make good points about buying safe products, this is the actual answer on why it will not work even if it was a perfectly safe socket.

    – SQB
    Jun 11 at 8:50












  • 1





    amazon.com/gp/aw/d/…. It says it is a 15amp device....but the paperwork says it is 220v

    – Steve
    Jun 9 at 23:06







  • 1





    Thanks @grawity

    – Kris
    Jun 10 at 14:59











  • While the other answers make good points about buying safe products, this is the actual answer on why it will not work even if it was a perfectly safe socket.

    – SQB
    Jun 11 at 8:50







1




1





amazon.com/gp/aw/d/…. It says it is a 15amp device....but the paperwork says it is 220v

– Steve
Jun 9 at 23:06






amazon.com/gp/aw/d/…. It says it is a 15amp device....but the paperwork says it is 220v

– Steve
Jun 9 at 23:06





1




1





Thanks @grawity

– Kris
Jun 10 at 14:59





Thanks @grawity

– Kris
Jun 10 at 14:59













While the other answers make good points about buying safe products, this is the actual answer on why it will not work even if it was a perfectly safe socket.

– SQB
Jun 11 at 8:50





While the other answers make good points about buying safe products, this is the actual answer on why it will not work even if it was a perfectly safe socket.

– SQB
Jun 11 at 8:50

















draft saved

draft discarded
















































Thanks for contributing an answer to Home Improvement Stack Exchange!


  • Please be sure to answer the question. Provide details and share your research!

But avoid


  • Asking for help, clarification, or responding to other answers.

  • Making statements based on opinion; back them up with references or personal experience.

To learn more, see our tips on writing great answers.




draft saved


draft discarded














StackExchange.ready(
function ()
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f166899%2fcan-i-use-220-v-outlets-on-a-15-ampere-breaker-and-wire-it-up-as-110-v%23new-answer', 'question_page');

);

Post as a guest















Required, but never shown





















































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown

































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown







Popular posts from this blog

Wikipedia:Vital articles Мазмуну Biography - Өмүр баян Philosophy and psychology - Философия жана психология Religion - Дин Social sciences - Коомдук илимдер Language and literature - Тил жана адабият Science - Илим Technology - Технология Arts and recreation - Искусство жана эс алуу History and geography - Тарых жана география Навигация менюсу

Club Baloncesto Breogán Índice Historia | Pavillón | Nome | O Breogán na cultura popular | Xogadores | Adestradores | Presidentes | Palmarés | Historial | Líderes | Notas | Véxase tamén | Menú de navegacióncbbreogan.galCadroGuía oficial da ACB 2009-10, páxina 201Guía oficial ACB 1992, páxina 183. Editorial DB.É de 6.500 espectadores sentados axeitándose á última normativa"Estudiantes Junior, entre as mellores canteiras"o orixinalHemeroteca El Mundo Deportivo, 16 setembro de 1970, páxina 12Historia do BreogánAlfredo Pérez, o último canoneiroHistoria C.B. BreogánHemeroteca de El Mundo DeportivoJimmy Wright, norteamericano do Breogán deixará Lugo por ameazas de morteResultados de Breogán en 1986-87Resultados de Breogán en 1990-91Ficha de Velimir Perasović en acb.comResultados de Breogán en 1994-95Breogán arrasa al Barça. "El Mundo Deportivo", 27 de setembro de 1999, páxina 58CB Breogán - FC BarcelonaA FEB invita a participar nunha nova Liga EuropeaCharlie Bell na prensa estatalMáximos anotadores 2005Tempada 2005-06 : Tódolos Xogadores da Xornada""Non quero pensar nunha man negra, mais pregúntome que está a pasar""o orixinalRaúl López, orgulloso dos xogadores, presume da boa saúde económica do BreogánJulio González confirma que cesa como presidente del BreogánHomenaxe a Lisardo GómezA tempada do rexurdimento celesteEntrevista a Lisardo GómezEl COB dinamita el Pazo para forzar el quinto (69-73)Cafés Candelas, patrocinador del CB Breogán"Suso Lázare, novo presidente do Breogán"o orixinalCafés Candelas Breogán firma el mayor triunfo de la historiaEl Breogán realizará 17 homenajes por su cincuenta aniversario"O Breogán honra ao seu fundador e primeiro presidente"o orixinalMiguel Giao recibiu a homenaxe do PazoHomenaxe aos primeiros gladiadores celestesO home que nos amosa como ver o Breo co corazónTita Franco será homenaxeada polos #50anosdeBreoJulio Vila recibirá unha homenaxe in memoriam polos #50anosdeBreo"O Breogán homenaxeará aos seus aboados máis veteráns"Pechada ovación a «Capi» Sanmartín e Ricardo «Corazón de González»Homenaxe por décadas de informaciónPaco García volve ao Pazo con motivo do 50 aniversario"Resultados y clasificaciones""O Cafés Candelas Breogán, campión da Copa Princesa""O Cafés Candelas Breogán, equipo ACB"C.B. Breogán"Proxecto social"o orixinal"Centros asociados"o orixinalFicha en imdb.comMario Camus trata la recuperación del amor en 'La vieja música', su última película"Páxina web oficial""Club Baloncesto Breogán""C. B. Breogán S.A.D."eehttp://www.fegaba.com

What should I write in an apology letter, since I have decided not to join a company after accepting an offer letterShould I keep looking after accepting a job offer?What should I do when I've been verbally told I would get an offer letter, but still haven't gotten one after 4 weeks?Do I accept an offer from a company that I am not likely to join?New job hasn't confirmed starting date and I want to give current employer as much notice as possibleHow should I address my manager in my resignation letter?HR delayed background verification, now jobless as resignedNo email communication after accepting a formal written offer. How should I phrase the call?What should I do if after receiving a verbal offer letter I am informed that my written job offer is put on hold due to some internal issues?Should I inform the current employer that I am about to resign within 1-2 weeks since I have signed the offer letter and waiting for visa?What company will do, if I send their offer letter to another company