What happens to foam insulation board after you pour concrete slab?

Why is gun control associated with the socially liberal Democratic party?

What are the mechanical differences between Adapt and Monstrosity?

2 Managed Packages in 1 Dev Org

Leveraging cash for buying car

I sent an angry e-mail to my interviewers about a conflict at my home institution. Could this affect my application?

100-doors puzzle

New Site Design!

What is this plant I saw for sale at a Romanian farmer's market?

Is the infant mortality rate among African-American babies in Youngstown, Ohio greater than that of babies in Iran?

Does knowing the surface area of all faces uniquely determine a tetrahedron?

How do I run a script as sudo at boot time on Ubuntu 18.04 Server?

Can a 40amp breaker be used safely and without issue with a 40amp device on 6AWG wire?

Fill the maze with a wall-following Snake until it gets stuck

High-end PC graphics circa 1990?

How useful is the GRE Exam?

Why does my system use more RAM after an hour of usage?

How can the US president give an order to a civilian?

Using roof rails to set up hammock

Digital signature that is only verifiable by one specific person

How did space travel spread through the galaxy?

First occurrence in the Sixers sequence

Basic power tool set for Home repair and simple projects

The instant an accelerating object has zero speed, is it speeding up, slowing down, or neither?

How could I create a situation in which a PC has to make a saving throw or be forced to pet a dog?



What happens to foam insulation board after you pour concrete slab?







.everyoneloves__top-leaderboard:empty,.everyoneloves__mid-leaderboard:empty,.everyoneloves__bot-mid-leaderboard:empty margin-bottom:0;








17















I plan on making a garage out of a large carport, and I've watched and I understood how to properly insulate a new concrete slab. 4 inches of gravel, vapor barrier, 2 inch foam board, 2 inches of sand and then 4-6 inches of poured concrete with mesh rebar in it.



My question is, how in the world will 2 inch foam board support all the concrete? Especially when I park both my trucks on top of it! Won't it crush in some parts and be uneven underground. Why does it make a good base?










share|improve this question

















  • 1





    If going to all the work to insulate why not put some poly line for hydronic heating, if you work in your garage in the winter it is really nice to have a warm floor. I did that with 1 bay in my last home and it almost kept the shop warm if I would have done all 3 I would not have needed the heater. But with hydronic heat it needs to be on for a long time so I used to keep mine at 50 and turn it up to 70 while I was in the shop.

    – Ed Beal
    May 30 at 22:03






  • 1





    I forgot to mention i'm going for this, good call

    – Jeffyx
    May 31 at 12:09

















17















I plan on making a garage out of a large carport, and I've watched and I understood how to properly insulate a new concrete slab. 4 inches of gravel, vapor barrier, 2 inch foam board, 2 inches of sand and then 4-6 inches of poured concrete with mesh rebar in it.



My question is, how in the world will 2 inch foam board support all the concrete? Especially when I park both my trucks on top of it! Won't it crush in some parts and be uneven underground. Why does it make a good base?










share|improve this question

















  • 1





    If going to all the work to insulate why not put some poly line for hydronic heating, if you work in your garage in the winter it is really nice to have a warm floor. I did that with 1 bay in my last home and it almost kept the shop warm if I would have done all 3 I would not have needed the heater. But with hydronic heat it needs to be on for a long time so I used to keep mine at 50 and turn it up to 70 while I was in the shop.

    – Ed Beal
    May 30 at 22:03






  • 1





    I forgot to mention i'm going for this, good call

    – Jeffyx
    May 31 at 12:09













17












17








17


1






I plan on making a garage out of a large carport, and I've watched and I understood how to properly insulate a new concrete slab. 4 inches of gravel, vapor barrier, 2 inch foam board, 2 inches of sand and then 4-6 inches of poured concrete with mesh rebar in it.



My question is, how in the world will 2 inch foam board support all the concrete? Especially when I park both my trucks on top of it! Won't it crush in some parts and be uneven underground. Why does it make a good base?










share|improve this question














I plan on making a garage out of a large carport, and I've watched and I understood how to properly insulate a new concrete slab. 4 inches of gravel, vapor barrier, 2 inch foam board, 2 inches of sand and then 4-6 inches of poured concrete with mesh rebar in it.



My question is, how in the world will 2 inch foam board support all the concrete? Especially when I park both my trucks on top of it! Won't it crush in some parts and be uneven underground. Why does it make a good base?







concrete insulation






share|improve this question













share|improve this question











share|improve this question




share|improve this question










asked May 30 at 21:21









JeffyxJeffyx

8817




8817







  • 1





    If going to all the work to insulate why not put some poly line for hydronic heating, if you work in your garage in the winter it is really nice to have a warm floor. I did that with 1 bay in my last home and it almost kept the shop warm if I would have done all 3 I would not have needed the heater. But with hydronic heat it needs to be on for a long time so I used to keep mine at 50 and turn it up to 70 while I was in the shop.

    – Ed Beal
    May 30 at 22:03






  • 1





    I forgot to mention i'm going for this, good call

    – Jeffyx
    May 31 at 12:09












  • 1





    If going to all the work to insulate why not put some poly line for hydronic heating, if you work in your garage in the winter it is really nice to have a warm floor. I did that with 1 bay in my last home and it almost kept the shop warm if I would have done all 3 I would not have needed the heater. But with hydronic heat it needs to be on for a long time so I used to keep mine at 50 and turn it up to 70 while I was in the shop.

    – Ed Beal
    May 30 at 22:03






  • 1





    I forgot to mention i'm going for this, good call

    – Jeffyx
    May 31 at 12:09







1




1





If going to all the work to insulate why not put some poly line for hydronic heating, if you work in your garage in the winter it is really nice to have a warm floor. I did that with 1 bay in my last home and it almost kept the shop warm if I would have done all 3 I would not have needed the heater. But with hydronic heat it needs to be on for a long time so I used to keep mine at 50 and turn it up to 70 while I was in the shop.

– Ed Beal
May 30 at 22:03





If going to all the work to insulate why not put some poly line for hydronic heating, if you work in your garage in the winter it is really nice to have a warm floor. I did that with 1 bay in my last home and it almost kept the shop warm if I would have done all 3 I would not have needed the heater. But with hydronic heat it needs to be on for a long time so I used to keep mine at 50 and turn it up to 70 while I was in the shop.

– Ed Beal
May 30 at 22:03




1




1





I forgot to mention i'm going for this, good call

– Jeffyx
May 31 at 12:09





I forgot to mention i'm going for this, good call

– Jeffyx
May 31 at 12:09










3 Answers
3






active

oldest

votes


















31














By way of example, the pink Owens-Corning FOAMULAR 250 product and the blue DOW STYROFOAM Brand SM product rated for 25 and 30 psi compressive strength respectively. If weight is distributed and applied evenly a square foot of FOAMULAR 250 could support 25*12*12=3600 pounds at its limit while the STYROFOAM could support 4320 pounds. A footnote in the data sheet qualifies this as "at yield or 10% deflection, whichever occurs first."



The weight of concrete varies but 150 pounds per cubic foot is a common approximation. Then a square foot of concrete, half a foot thick, should weigh about 75 pounds. That leaves at least 3500 pounds of weight carrying capacity before the foam below the concrete would fail.



The weight of a vehicle sits on the contact patch of its tires. If we consider a hypothetical 8000 pound pickup truck with 70% of its weight on the front tires, that's 2800 pounds per tire. (Maybe a 70/30 distribution of weight is extreme; I don't know.)



The tire contact patch is much smaller than the square foot we've been thinking about, so it would seem that the load might be too concentrated and would crush the foam. Indeed if the tire rolled directly over the foam it likely would be crushed. Fortunately the reinforced concrete does a pretty good job of spreading the load. The weight on that tire contact patch is spread over a larger area of foam and it all works out.



On a related note, enormous foam blocks can be used instead of soil as fill in construction projects like bridge abutments, roadways, etc. See Geofoam.






share|improve this answer























  • That geofoam is amazing stuff. Also thanks for showing me the math!

    – Jeffyx
    May 31 at 12:12











  • You don't need to do any hard math to turn an automobile's weight or distribution into earth-crush PSI... just stick a $5 tire gauge on it and measure the PSI of your tires. Yeah, it really is that simple.

    – Harper
    Jun 1 at 6:14












  • @Harper Assuming that you start with atmospheric pressure in the tires or what?

    – Alex
    Jun 1 at 16:31






  • 1





    @Harper That would give you a maximum possible value in that case. A lightweight racing bicycle with 110psi tires would obviously not give you 110 psi earth crushing power, and it would roll over the styrofoam just fine.

    – Alex
    Jun 2 at 0:27







  • 1





    @RossMillikan Real tires, in contrast to theoreticall ones, have rubber between the compressed air and the ground. Rubber is soft and deforms on its own, even if the airpocket inside would have been filled with hard solid steel. The contact area is not linear with the internal pressure when you get up to high pressures.

    – Alex
    Jun 2 at 7:39


















3














Foam insulation is designed with a loading value per unit area and as long as that loading is not exceeded it will not deform.



When we designed the insulation for the base of our property we specified an 8” thickness of a particular grade of foam board. The builder ordered a different board and we had to check to see if it was sufficiently strong - luckily it was...






share|improve this answer






























    3














    XPS and EPS rigid insulation is used under concrete slabs.



    They both come in various rated compressive strengths from 10 psi to about 80 psi.



    Say you use an average (and relatively inexpensive) rating of 40 psi, then the insulation will support: 40 psi x 8” wide tire x 12” long tire print = 3,840 lbs. at each tire. (Total load supported would be: 3,840 lbs. x 4 tires = 15,360 lbs. )



    Actually, the maximum load would be significantly more, because the load would be transferred through the slab at a 45 degree angle. So, the actual “footprint “ on the insulation would be about double the area...thus double the allowable load.



    Here’s a site that explains the use of rigid insulation under slabs. https://www.concreteconstruction.net/how-to/site-prep/choosing-between-eps-and-xps-rigid-insulation_o



    There is some logic to not using insulation, unless the garage is being heated.



    BTW, I don’t recommend the use of wire mesh in garage slabs. They make them crack.






    share|improve this answer























    • I worked with concrete for years as a foreman, I would tell customers two guarantees about concrete: 1) It will harden 2) It will crack. You add control joints in concrete to control where it will crack. If you don't, it will crack along the line of least resistance, which will be along any rebar or along any wire mesh. Adding of that "BTW" weakens this answer.

      – Keeta
      May 31 at 12:01











    • I'm guessing you're used to working with heavy trucks if you think an 8"x12" contact patch is what springs to mind!

      – FreeMan
      May 31 at 13:22











    • @Keeta Yes, control joints are a must, but wire mesh “creates” cracks because it’s too small and gets pushed to the bottom of the slab and is allowed to extend through the control joints. Rebar in slabs is fine if installed in the middle of the slab.

      – Lee Sam
      May 31 at 14:45











    Your Answer








    StackExchange.ready(function()
    var channelOptions =
    tags: "".split(" "),
    id: "73"
    ;
    initTagRenderer("".split(" "), "".split(" "), channelOptions);

    StackExchange.using("externalEditor", function()
    // Have to fire editor after snippets, if snippets enabled
    if (StackExchange.settings.snippets.snippetsEnabled)
    StackExchange.using("snippets", function()
    createEditor();
    );

    else
    createEditor();

    );

    function createEditor()
    StackExchange.prepareEditor(
    heartbeatType: 'answer',
    autoActivateHeartbeat: false,
    convertImagesToLinks: false,
    noModals: true,
    showLowRepImageUploadWarning: true,
    reputationToPostImages: null,
    bindNavPrevention: true,
    postfix: "",
    imageUploader:
    brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
    contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
    allowUrls: true
    ,
    noCode: true, onDemand: true,
    discardSelector: ".discard-answer"
    ,immediatelyShowMarkdownHelp:true
    );



    );













    draft saved

    draft discarded


















    StackExchange.ready(
    function ()
    StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f166283%2fwhat-happens-to-foam-insulation-board-after-you-pour-concrete-slab%23new-answer', 'question_page');

    );

    Post as a guest















    Required, but never shown

























    3 Answers
    3






    active

    oldest

    votes








    3 Answers
    3






    active

    oldest

    votes









    active

    oldest

    votes






    active

    oldest

    votes









    31














    By way of example, the pink Owens-Corning FOAMULAR 250 product and the blue DOW STYROFOAM Brand SM product rated for 25 and 30 psi compressive strength respectively. If weight is distributed and applied evenly a square foot of FOAMULAR 250 could support 25*12*12=3600 pounds at its limit while the STYROFOAM could support 4320 pounds. A footnote in the data sheet qualifies this as "at yield or 10% deflection, whichever occurs first."



    The weight of concrete varies but 150 pounds per cubic foot is a common approximation. Then a square foot of concrete, half a foot thick, should weigh about 75 pounds. That leaves at least 3500 pounds of weight carrying capacity before the foam below the concrete would fail.



    The weight of a vehicle sits on the contact patch of its tires. If we consider a hypothetical 8000 pound pickup truck with 70% of its weight on the front tires, that's 2800 pounds per tire. (Maybe a 70/30 distribution of weight is extreme; I don't know.)



    The tire contact patch is much smaller than the square foot we've been thinking about, so it would seem that the load might be too concentrated and would crush the foam. Indeed if the tire rolled directly over the foam it likely would be crushed. Fortunately the reinforced concrete does a pretty good job of spreading the load. The weight on that tire contact patch is spread over a larger area of foam and it all works out.



    On a related note, enormous foam blocks can be used instead of soil as fill in construction projects like bridge abutments, roadways, etc. See Geofoam.






    share|improve this answer























    • That geofoam is amazing stuff. Also thanks for showing me the math!

      – Jeffyx
      May 31 at 12:12











    • You don't need to do any hard math to turn an automobile's weight or distribution into earth-crush PSI... just stick a $5 tire gauge on it and measure the PSI of your tires. Yeah, it really is that simple.

      – Harper
      Jun 1 at 6:14












    • @Harper Assuming that you start with atmospheric pressure in the tires or what?

      – Alex
      Jun 1 at 16:31






    • 1





      @Harper That would give you a maximum possible value in that case. A lightweight racing bicycle with 110psi tires would obviously not give you 110 psi earth crushing power, and it would roll over the styrofoam just fine.

      – Alex
      Jun 2 at 0:27







    • 1





      @RossMillikan Real tires, in contrast to theoreticall ones, have rubber between the compressed air and the ground. Rubber is soft and deforms on its own, even if the airpocket inside would have been filled with hard solid steel. The contact area is not linear with the internal pressure when you get up to high pressures.

      – Alex
      Jun 2 at 7:39















    31














    By way of example, the pink Owens-Corning FOAMULAR 250 product and the blue DOW STYROFOAM Brand SM product rated for 25 and 30 psi compressive strength respectively. If weight is distributed and applied evenly a square foot of FOAMULAR 250 could support 25*12*12=3600 pounds at its limit while the STYROFOAM could support 4320 pounds. A footnote in the data sheet qualifies this as "at yield or 10% deflection, whichever occurs first."



    The weight of concrete varies but 150 pounds per cubic foot is a common approximation. Then a square foot of concrete, half a foot thick, should weigh about 75 pounds. That leaves at least 3500 pounds of weight carrying capacity before the foam below the concrete would fail.



    The weight of a vehicle sits on the contact patch of its tires. If we consider a hypothetical 8000 pound pickup truck with 70% of its weight on the front tires, that's 2800 pounds per tire. (Maybe a 70/30 distribution of weight is extreme; I don't know.)



    The tire contact patch is much smaller than the square foot we've been thinking about, so it would seem that the load might be too concentrated and would crush the foam. Indeed if the tire rolled directly over the foam it likely would be crushed. Fortunately the reinforced concrete does a pretty good job of spreading the load. The weight on that tire contact patch is spread over a larger area of foam and it all works out.



    On a related note, enormous foam blocks can be used instead of soil as fill in construction projects like bridge abutments, roadways, etc. See Geofoam.






    share|improve this answer























    • That geofoam is amazing stuff. Also thanks for showing me the math!

      – Jeffyx
      May 31 at 12:12











    • You don't need to do any hard math to turn an automobile's weight or distribution into earth-crush PSI... just stick a $5 tire gauge on it and measure the PSI of your tires. Yeah, it really is that simple.

      – Harper
      Jun 1 at 6:14












    • @Harper Assuming that you start with atmospheric pressure in the tires or what?

      – Alex
      Jun 1 at 16:31






    • 1





      @Harper That would give you a maximum possible value in that case. A lightweight racing bicycle with 110psi tires would obviously not give you 110 psi earth crushing power, and it would roll over the styrofoam just fine.

      – Alex
      Jun 2 at 0:27







    • 1





      @RossMillikan Real tires, in contrast to theoreticall ones, have rubber between the compressed air and the ground. Rubber is soft and deforms on its own, even if the airpocket inside would have been filled with hard solid steel. The contact area is not linear with the internal pressure when you get up to high pressures.

      – Alex
      Jun 2 at 7:39













    31












    31








    31







    By way of example, the pink Owens-Corning FOAMULAR 250 product and the blue DOW STYROFOAM Brand SM product rated for 25 and 30 psi compressive strength respectively. If weight is distributed and applied evenly a square foot of FOAMULAR 250 could support 25*12*12=3600 pounds at its limit while the STYROFOAM could support 4320 pounds. A footnote in the data sheet qualifies this as "at yield or 10% deflection, whichever occurs first."



    The weight of concrete varies but 150 pounds per cubic foot is a common approximation. Then a square foot of concrete, half a foot thick, should weigh about 75 pounds. That leaves at least 3500 pounds of weight carrying capacity before the foam below the concrete would fail.



    The weight of a vehicle sits on the contact patch of its tires. If we consider a hypothetical 8000 pound pickup truck with 70% of its weight on the front tires, that's 2800 pounds per tire. (Maybe a 70/30 distribution of weight is extreme; I don't know.)



    The tire contact patch is much smaller than the square foot we've been thinking about, so it would seem that the load might be too concentrated and would crush the foam. Indeed if the tire rolled directly over the foam it likely would be crushed. Fortunately the reinforced concrete does a pretty good job of spreading the load. The weight on that tire contact patch is spread over a larger area of foam and it all works out.



    On a related note, enormous foam blocks can be used instead of soil as fill in construction projects like bridge abutments, roadways, etc. See Geofoam.






    share|improve this answer













    By way of example, the pink Owens-Corning FOAMULAR 250 product and the blue DOW STYROFOAM Brand SM product rated for 25 and 30 psi compressive strength respectively. If weight is distributed and applied evenly a square foot of FOAMULAR 250 could support 25*12*12=3600 pounds at its limit while the STYROFOAM could support 4320 pounds. A footnote in the data sheet qualifies this as "at yield or 10% deflection, whichever occurs first."



    The weight of concrete varies but 150 pounds per cubic foot is a common approximation. Then a square foot of concrete, half a foot thick, should weigh about 75 pounds. That leaves at least 3500 pounds of weight carrying capacity before the foam below the concrete would fail.



    The weight of a vehicle sits on the contact patch of its tires. If we consider a hypothetical 8000 pound pickup truck with 70% of its weight on the front tires, that's 2800 pounds per tire. (Maybe a 70/30 distribution of weight is extreme; I don't know.)



    The tire contact patch is much smaller than the square foot we've been thinking about, so it would seem that the load might be too concentrated and would crush the foam. Indeed if the tire rolled directly over the foam it likely would be crushed. Fortunately the reinforced concrete does a pretty good job of spreading the load. The weight on that tire contact patch is spread over a larger area of foam and it all works out.



    On a related note, enormous foam blocks can be used instead of soil as fill in construction projects like bridge abutments, roadways, etc. See Geofoam.







    share|improve this answer












    share|improve this answer



    share|improve this answer










    answered May 30 at 22:47









    Greg HillGreg Hill

    1,19158




    1,19158












    • That geofoam is amazing stuff. Also thanks for showing me the math!

      – Jeffyx
      May 31 at 12:12











    • You don't need to do any hard math to turn an automobile's weight or distribution into earth-crush PSI... just stick a $5 tire gauge on it and measure the PSI of your tires. Yeah, it really is that simple.

      – Harper
      Jun 1 at 6:14












    • @Harper Assuming that you start with atmospheric pressure in the tires or what?

      – Alex
      Jun 1 at 16:31






    • 1





      @Harper That would give you a maximum possible value in that case. A lightweight racing bicycle with 110psi tires would obviously not give you 110 psi earth crushing power, and it would roll over the styrofoam just fine.

      – Alex
      Jun 2 at 0:27







    • 1





      @RossMillikan Real tires, in contrast to theoreticall ones, have rubber between the compressed air and the ground. Rubber is soft and deforms on its own, even if the airpocket inside would have been filled with hard solid steel. The contact area is not linear with the internal pressure when you get up to high pressures.

      – Alex
      Jun 2 at 7:39

















    • That geofoam is amazing stuff. Also thanks for showing me the math!

      – Jeffyx
      May 31 at 12:12











    • You don't need to do any hard math to turn an automobile's weight or distribution into earth-crush PSI... just stick a $5 tire gauge on it and measure the PSI of your tires. Yeah, it really is that simple.

      – Harper
      Jun 1 at 6:14












    • @Harper Assuming that you start with atmospheric pressure in the tires or what?

      – Alex
      Jun 1 at 16:31






    • 1





      @Harper That would give you a maximum possible value in that case. A lightweight racing bicycle with 110psi tires would obviously not give you 110 psi earth crushing power, and it would roll over the styrofoam just fine.

      – Alex
      Jun 2 at 0:27







    • 1





      @RossMillikan Real tires, in contrast to theoreticall ones, have rubber between the compressed air and the ground. Rubber is soft and deforms on its own, even if the airpocket inside would have been filled with hard solid steel. The contact area is not linear with the internal pressure when you get up to high pressures.

      – Alex
      Jun 2 at 7:39
















    That geofoam is amazing stuff. Also thanks for showing me the math!

    – Jeffyx
    May 31 at 12:12





    That geofoam is amazing stuff. Also thanks for showing me the math!

    – Jeffyx
    May 31 at 12:12













    You don't need to do any hard math to turn an automobile's weight or distribution into earth-crush PSI... just stick a $5 tire gauge on it and measure the PSI of your tires. Yeah, it really is that simple.

    – Harper
    Jun 1 at 6:14






    You don't need to do any hard math to turn an automobile's weight or distribution into earth-crush PSI... just stick a $5 tire gauge on it and measure the PSI of your tires. Yeah, it really is that simple.

    – Harper
    Jun 1 at 6:14














    @Harper Assuming that you start with atmospheric pressure in the tires or what?

    – Alex
    Jun 1 at 16:31





    @Harper Assuming that you start with atmospheric pressure in the tires or what?

    – Alex
    Jun 1 at 16:31




    1




    1





    @Harper That would give you a maximum possible value in that case. A lightweight racing bicycle with 110psi tires would obviously not give you 110 psi earth crushing power, and it would roll over the styrofoam just fine.

    – Alex
    Jun 2 at 0:27






    @Harper That would give you a maximum possible value in that case. A lightweight racing bicycle with 110psi tires would obviously not give you 110 psi earth crushing power, and it would roll over the styrofoam just fine.

    – Alex
    Jun 2 at 0:27





    1




    1





    @RossMillikan Real tires, in contrast to theoreticall ones, have rubber between the compressed air and the ground. Rubber is soft and deforms on its own, even if the airpocket inside would have been filled with hard solid steel. The contact area is not linear with the internal pressure when you get up to high pressures.

    – Alex
    Jun 2 at 7:39





    @RossMillikan Real tires, in contrast to theoreticall ones, have rubber between the compressed air and the ground. Rubber is soft and deforms on its own, even if the airpocket inside would have been filled with hard solid steel. The contact area is not linear with the internal pressure when you get up to high pressures.

    – Alex
    Jun 2 at 7:39













    3














    Foam insulation is designed with a loading value per unit area and as long as that loading is not exceeded it will not deform.



    When we designed the insulation for the base of our property we specified an 8” thickness of a particular grade of foam board. The builder ordered a different board and we had to check to see if it was sufficiently strong - luckily it was...






    share|improve this answer



























      3














      Foam insulation is designed with a loading value per unit area and as long as that loading is not exceeded it will not deform.



      When we designed the insulation for the base of our property we specified an 8” thickness of a particular grade of foam board. The builder ordered a different board and we had to check to see if it was sufficiently strong - luckily it was...






      share|improve this answer

























        3












        3








        3







        Foam insulation is designed with a loading value per unit area and as long as that loading is not exceeded it will not deform.



        When we designed the insulation for the base of our property we specified an 8” thickness of a particular grade of foam board. The builder ordered a different board and we had to check to see if it was sufficiently strong - luckily it was...






        share|improve this answer













        Foam insulation is designed with a loading value per unit area and as long as that loading is not exceeded it will not deform.



        When we designed the insulation for the base of our property we specified an 8” thickness of a particular grade of foam board. The builder ordered a different board and we had to check to see if it was sufficiently strong - luckily it was...







        share|improve this answer












        share|improve this answer



        share|improve this answer










        answered May 30 at 21:30









        Solar MikeSolar Mike

        2,8211313




        2,8211313





















            3














            XPS and EPS rigid insulation is used under concrete slabs.



            They both come in various rated compressive strengths from 10 psi to about 80 psi.



            Say you use an average (and relatively inexpensive) rating of 40 psi, then the insulation will support: 40 psi x 8” wide tire x 12” long tire print = 3,840 lbs. at each tire. (Total load supported would be: 3,840 lbs. x 4 tires = 15,360 lbs. )



            Actually, the maximum load would be significantly more, because the load would be transferred through the slab at a 45 degree angle. So, the actual “footprint “ on the insulation would be about double the area...thus double the allowable load.



            Here’s a site that explains the use of rigid insulation under slabs. https://www.concreteconstruction.net/how-to/site-prep/choosing-between-eps-and-xps-rigid-insulation_o



            There is some logic to not using insulation, unless the garage is being heated.



            BTW, I don’t recommend the use of wire mesh in garage slabs. They make them crack.






            share|improve this answer























            • I worked with concrete for years as a foreman, I would tell customers two guarantees about concrete: 1) It will harden 2) It will crack. You add control joints in concrete to control where it will crack. If you don't, it will crack along the line of least resistance, which will be along any rebar or along any wire mesh. Adding of that "BTW" weakens this answer.

              – Keeta
              May 31 at 12:01











            • I'm guessing you're used to working with heavy trucks if you think an 8"x12" contact patch is what springs to mind!

              – FreeMan
              May 31 at 13:22











            • @Keeta Yes, control joints are a must, but wire mesh “creates” cracks because it’s too small and gets pushed to the bottom of the slab and is allowed to extend through the control joints. Rebar in slabs is fine if installed in the middle of the slab.

              – Lee Sam
              May 31 at 14:45















            3














            XPS and EPS rigid insulation is used under concrete slabs.



            They both come in various rated compressive strengths from 10 psi to about 80 psi.



            Say you use an average (and relatively inexpensive) rating of 40 psi, then the insulation will support: 40 psi x 8” wide tire x 12” long tire print = 3,840 lbs. at each tire. (Total load supported would be: 3,840 lbs. x 4 tires = 15,360 lbs. )



            Actually, the maximum load would be significantly more, because the load would be transferred through the slab at a 45 degree angle. So, the actual “footprint “ on the insulation would be about double the area...thus double the allowable load.



            Here’s a site that explains the use of rigid insulation under slabs. https://www.concreteconstruction.net/how-to/site-prep/choosing-between-eps-and-xps-rigid-insulation_o



            There is some logic to not using insulation, unless the garage is being heated.



            BTW, I don’t recommend the use of wire mesh in garage slabs. They make them crack.






            share|improve this answer























            • I worked with concrete for years as a foreman, I would tell customers two guarantees about concrete: 1) It will harden 2) It will crack. You add control joints in concrete to control where it will crack. If you don't, it will crack along the line of least resistance, which will be along any rebar or along any wire mesh. Adding of that "BTW" weakens this answer.

              – Keeta
              May 31 at 12:01











            • I'm guessing you're used to working with heavy trucks if you think an 8"x12" contact patch is what springs to mind!

              – FreeMan
              May 31 at 13:22











            • @Keeta Yes, control joints are a must, but wire mesh “creates” cracks because it’s too small and gets pushed to the bottom of the slab and is allowed to extend through the control joints. Rebar in slabs is fine if installed in the middle of the slab.

              – Lee Sam
              May 31 at 14:45













            3












            3








            3







            XPS and EPS rigid insulation is used under concrete slabs.



            They both come in various rated compressive strengths from 10 psi to about 80 psi.



            Say you use an average (and relatively inexpensive) rating of 40 psi, then the insulation will support: 40 psi x 8” wide tire x 12” long tire print = 3,840 lbs. at each tire. (Total load supported would be: 3,840 lbs. x 4 tires = 15,360 lbs. )



            Actually, the maximum load would be significantly more, because the load would be transferred through the slab at a 45 degree angle. So, the actual “footprint “ on the insulation would be about double the area...thus double the allowable load.



            Here’s a site that explains the use of rigid insulation under slabs. https://www.concreteconstruction.net/how-to/site-prep/choosing-between-eps-and-xps-rigid-insulation_o



            There is some logic to not using insulation, unless the garage is being heated.



            BTW, I don’t recommend the use of wire mesh in garage slabs. They make them crack.






            share|improve this answer













            XPS and EPS rigid insulation is used under concrete slabs.



            They both come in various rated compressive strengths from 10 psi to about 80 psi.



            Say you use an average (and relatively inexpensive) rating of 40 psi, then the insulation will support: 40 psi x 8” wide tire x 12” long tire print = 3,840 lbs. at each tire. (Total load supported would be: 3,840 lbs. x 4 tires = 15,360 lbs. )



            Actually, the maximum load would be significantly more, because the load would be transferred through the slab at a 45 degree angle. So, the actual “footprint “ on the insulation would be about double the area...thus double the allowable load.



            Here’s a site that explains the use of rigid insulation under slabs. https://www.concreteconstruction.net/how-to/site-prep/choosing-between-eps-and-xps-rigid-insulation_o



            There is some logic to not using insulation, unless the garage is being heated.



            BTW, I don’t recommend the use of wire mesh in garage slabs. They make them crack.







            share|improve this answer












            share|improve this answer



            share|improve this answer










            answered May 30 at 22:02









            Lee SamLee Sam

            12.1k3820




            12.1k3820












            • I worked with concrete for years as a foreman, I would tell customers two guarantees about concrete: 1) It will harden 2) It will crack. You add control joints in concrete to control where it will crack. If you don't, it will crack along the line of least resistance, which will be along any rebar or along any wire mesh. Adding of that "BTW" weakens this answer.

              – Keeta
              May 31 at 12:01











            • I'm guessing you're used to working with heavy trucks if you think an 8"x12" contact patch is what springs to mind!

              – FreeMan
              May 31 at 13:22











            • @Keeta Yes, control joints are a must, but wire mesh “creates” cracks because it’s too small and gets pushed to the bottom of the slab and is allowed to extend through the control joints. Rebar in slabs is fine if installed in the middle of the slab.

              – Lee Sam
              May 31 at 14:45

















            • I worked with concrete for years as a foreman, I would tell customers two guarantees about concrete: 1) It will harden 2) It will crack. You add control joints in concrete to control where it will crack. If you don't, it will crack along the line of least resistance, which will be along any rebar or along any wire mesh. Adding of that "BTW" weakens this answer.

              – Keeta
              May 31 at 12:01











            • I'm guessing you're used to working with heavy trucks if you think an 8"x12" contact patch is what springs to mind!

              – FreeMan
              May 31 at 13:22











            • @Keeta Yes, control joints are a must, but wire mesh “creates” cracks because it’s too small and gets pushed to the bottom of the slab and is allowed to extend through the control joints. Rebar in slabs is fine if installed in the middle of the slab.

              – Lee Sam
              May 31 at 14:45
















            I worked with concrete for years as a foreman, I would tell customers two guarantees about concrete: 1) It will harden 2) It will crack. You add control joints in concrete to control where it will crack. If you don't, it will crack along the line of least resistance, which will be along any rebar or along any wire mesh. Adding of that "BTW" weakens this answer.

            – Keeta
            May 31 at 12:01





            I worked with concrete for years as a foreman, I would tell customers two guarantees about concrete: 1) It will harden 2) It will crack. You add control joints in concrete to control where it will crack. If you don't, it will crack along the line of least resistance, which will be along any rebar or along any wire mesh. Adding of that "BTW" weakens this answer.

            – Keeta
            May 31 at 12:01













            I'm guessing you're used to working with heavy trucks if you think an 8"x12" contact patch is what springs to mind!

            – FreeMan
            May 31 at 13:22





            I'm guessing you're used to working with heavy trucks if you think an 8"x12" contact patch is what springs to mind!

            – FreeMan
            May 31 at 13:22













            @Keeta Yes, control joints are a must, but wire mesh “creates” cracks because it’s too small and gets pushed to the bottom of the slab and is allowed to extend through the control joints. Rebar in slabs is fine if installed in the middle of the slab.

            – Lee Sam
            May 31 at 14:45





            @Keeta Yes, control joints are a must, but wire mesh “creates” cracks because it’s too small and gets pushed to the bottom of the slab and is allowed to extend through the control joints. Rebar in slabs is fine if installed in the middle of the slab.

            – Lee Sam
            May 31 at 14:45

















            draft saved

            draft discarded
















































            Thanks for contributing an answer to Home Improvement Stack Exchange!


            • Please be sure to answer the question. Provide details and share your research!

            But avoid


            • Asking for help, clarification, or responding to other answers.

            • Making statements based on opinion; back them up with references or personal experience.

            To learn more, see our tips on writing great answers.




            draft saved


            draft discarded














            StackExchange.ready(
            function ()
            StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f166283%2fwhat-happens-to-foam-insulation-board-after-you-pour-concrete-slab%23new-answer', 'question_page');

            );

            Post as a guest















            Required, but never shown





















































            Required, but never shown














            Required, but never shown












            Required, but never shown







            Required, but never shown

































            Required, but never shown














            Required, but never shown












            Required, but never shown







            Required, but never shown







            Popular posts from this blog

            Club Baloncesto Breogán Índice Historia | Pavillón | Nome | O Breogán na cultura popular | Xogadores | Adestradores | Presidentes | Palmarés | Historial | Líderes | Notas | Véxase tamén | Menú de navegacióncbbreogan.galCadroGuía oficial da ACB 2009-10, páxina 201Guía oficial ACB 1992, páxina 183. Editorial DB.É de 6.500 espectadores sentados axeitándose á última normativa"Estudiantes Junior, entre as mellores canteiras"o orixinalHemeroteca El Mundo Deportivo, 16 setembro de 1970, páxina 12Historia do BreogánAlfredo Pérez, o último canoneiroHistoria C.B. BreogánHemeroteca de El Mundo DeportivoJimmy Wright, norteamericano do Breogán deixará Lugo por ameazas de morteResultados de Breogán en 1986-87Resultados de Breogán en 1990-91Ficha de Velimir Perasović en acb.comResultados de Breogán en 1994-95Breogán arrasa al Barça. "El Mundo Deportivo", 27 de setembro de 1999, páxina 58CB Breogán - FC BarcelonaA FEB invita a participar nunha nova Liga EuropeaCharlie Bell na prensa estatalMáximos anotadores 2005Tempada 2005-06 : Tódolos Xogadores da Xornada""Non quero pensar nunha man negra, mais pregúntome que está a pasar""o orixinalRaúl López, orgulloso dos xogadores, presume da boa saúde económica do BreogánJulio González confirma que cesa como presidente del BreogánHomenaxe a Lisardo GómezA tempada do rexurdimento celesteEntrevista a Lisardo GómezEl COB dinamita el Pazo para forzar el quinto (69-73)Cafés Candelas, patrocinador del CB Breogán"Suso Lázare, novo presidente do Breogán"o orixinalCafés Candelas Breogán firma el mayor triunfo de la historiaEl Breogán realizará 17 homenajes por su cincuenta aniversario"O Breogán honra ao seu fundador e primeiro presidente"o orixinalMiguel Giao recibiu a homenaxe do PazoHomenaxe aos primeiros gladiadores celestesO home que nos amosa como ver o Breo co corazónTita Franco será homenaxeada polos #50anosdeBreoJulio Vila recibirá unha homenaxe in memoriam polos #50anosdeBreo"O Breogán homenaxeará aos seus aboados máis veteráns"Pechada ovación a «Capi» Sanmartín e Ricardo «Corazón de González»Homenaxe por décadas de informaciónPaco García volve ao Pazo con motivo do 50 aniversario"Resultados y clasificaciones""O Cafés Candelas Breogán, campión da Copa Princesa""O Cafés Candelas Breogán, equipo ACB"C.B. Breogán"Proxecto social"o orixinal"Centros asociados"o orixinalFicha en imdb.comMario Camus trata la recuperación del amor en 'La vieja música', su última película"Páxina web oficial""Club Baloncesto Breogán""C. B. Breogán S.A.D."eehttp://www.fegaba.com

            Vilaño, A Laracha Índice Patrimonio | Lugares e parroquias | Véxase tamén | Menú de navegación43°14′52″N 8°36′03″O / 43.24775, -8.60070

            Cegueira Índice Epidemioloxía | Deficiencia visual | Tipos de cegueira | Principais causas de cegueira | Tratamento | Técnicas de adaptación e axudas | Vida dos cegos | Primeiros auxilios | Crenzas respecto das persoas cegas | Crenzas das persoas cegas | O neno deficiente visual | Aspectos psicolóxicos da cegueira | Notas | Véxase tamén | Menú de navegación54.054.154.436928256blindnessDicionario da Real Academia GalegaPortal das Palabras"International Standards: Visual Standards — Aspects and Ranges of Vision Loss with Emphasis on Population Surveys.""Visual impairment and blindness""Presentan un plan para previr a cegueira"o orixinalACCDV Associació Catalana de Cecs i Disminuïts Visuals - PMFTrachoma"Effect of gene therapy on visual function in Leber's congenital amaurosis"1844137110.1056/NEJMoa0802268Cans guía - os mellores amigos dos cegosArquivadoEscola de cans guía para cegos en Mortágua, PortugalArquivado"Tecnología para ciegos y deficientes visuales. Recopilación de recursos gratuitos en la Red""Colorino""‘COL.diesis’, escuchar los sonidos del color""COL.diesis: Transforming Colour into Melody and Implementing the Result in a Colour Sensor Device"o orixinal"Sistema de desarrollo de sinestesia color-sonido para invidentes utilizando un protocolo de audio""Enseñanza táctil - geometría y color. Juegos didácticos para niños ciegos y videntes""Sistema Constanz"L'ocupació laboral dels cecs a l'Estat espanyol està pràcticament equiparada a la de les persones amb visió, entrevista amb Pedro ZuritaONCE (Organización Nacional de Cegos de España)Prevención da cegueiraDescrición de deficiencias visuais (Disc@pnet)Braillín, un boneco atractivo para calquera neno, con ou sen discapacidade, que permite familiarizarse co sistema de escritura e lectura brailleAxudas Técnicas36838ID00897494007150-90057129528256DOID:1432HP:0000618D001766C10.597.751.941.162C97109C0155020